Описание оборудования | |
---|---|
Diffuse mode sensor | |
General specifications | |
Detection range | 2 ... 1400 mm |
Detection range min. | 100 ... 200 mm |
Detection range max. | 2 ... 1400 mm |
Adjustment range | 200 ... 1400 mm |
Reference target | standard white, 100 mm x 100 mm |
Light source | LED |
Light type | modulated visible red light |
LED risk group labelling | exempt group |
Diameter of the light spot | approx. 50 mm at a distance of 1400 mm |
Angle of divergence | 2 ° |
Ambient light limit | EN 60947-5-2 : 60000 Lux |
Functional safety related parameters | |
MTTFd | 724 a |
Mission Time (TM) | 20 a |
Diagnostic Coverage (DC) | 0 % |
Indicators/operating means | |
Operation indicator | LED green: constantly on - power on flashing (4Hz) - short circuit flashing with short break (1 Hz) - IO-Link mode |
Function indicator | LED yellow: constantly on - object detected constantly off - object not detected |
Control elements | Light-on/dark-on changeover switch |
Control elements | Sensing range adjuster |
Electrical specifications | |
Operating voltage | 10 ... 30 V DC |
Ripple | max. 10 % |
No-load supply current | < 18 mA at 24 V Operating voltage |
Protection class | III |
Interface | |
Interface type | IO-Link ( via C/Q = pin 4 ) |
Device profile | Identification and diagnosis Smart Sensor type 2.4 |
Transfer rate | COM2 (38.4 kBaud) |
IO-Link Revision | 1.1 |
Min. cycle time | 2.3 ms |
Process data witdh | Process data input 1Bit Process data output 2Bit |
SIO mode support | yes |
Device ID | 0x111101 (1118465) |
Compatible master port type | A |
Output | |
Switching type | The switching type of the sensor is adjustable. The default setting is: C/Q - Pin4: NPN normally open / light-on, PNP normally closed / dark-on, IO-Link |
Signal output | 1 push-pull (4 in 1) output, short-circuit protected, reverse polarity protected, overvoltage protected |
Switching voltage | max. 30 V DC |
Switching current | max. 100 mA , resistive load |
Usage category | DC-12 and DC-13 |
Voltage drop | ? 1.5 V DC |
Switching frequency | 1000 Hz |
Response time | 0.5 ms |
Conformity | |
Communication interface | IEC 61131-9 |
Product standard | EN 60947-5-2 |
Approvals and certificates | |
UL approval | E87056 , cULus Listed , class 2 power supply , type rating 1 |
CCC approval | CCC approval / marking not required for products rated ?36 V |
Ambient conditions | |
Ambient temperature |